language
Category
digital
About This Project

Surtron-400-HP-Vessel-Sealing_frontal

SURTRON 400 HP can be used to simultaneously perform monopolar and bipolar surgery in application fields which require high precision and reliability.

 

 

UNDERWATER CUTTING AND COAGULATION

 

DOUBLE ACTIVITY ‘OPERATION
• Two output channels for monopolar cutting
• Two independent setting and output channels for monopolar coagulation more frequently

CONTROLLED CUTTING PROCEDURES
• cutting currents for eschar free incision
• Cutting current with selectable coagulating property for bleeding controlled dissection
• Low capacitive coupling by current endoscopic procedures Slow BLEND

DOUBLE PROCEDURES SUBSIDIARIES COAGULATION
• SPEEDY Coag Coag DEEP ** * and two operators
• SPRAY COAG achievable with handpiece or pedal

WIDE BIPOLAR FEATURES
• Bipolar cutting with bleeding control
• Cutting current Slow BLEND
• Start and Stop automatic activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON
• Acceptability of contact impedance between the patient’s body and the neutral plate constantly verified by the electronic control Skin Plate Electronic Control called SPEC
• Continuous monitoring of leakage current
• Change in automatically compensated mains voltage before starting the RF power output

CUSTOM PROCEDURES
• Independent choice of coagulation currents and power levels of each of the two operators
• Ten configurable personal procedures and immediately recallable

CONDUCT OF EXTENSIONS AND SIGNAL CONNECTION
• outputs for connections driven argon plasma units and smoke aspirator

AUTOMATIC SELF-DIAGNOSIS WITH SURTRON 400 HP
• Automatic diagnostic control of the actual complete electronic drive functionality and accessories connected and coded report of found failures

* Coag SPEEDY is also called Fulgurate or Forced
** Coag DEEP is also called Pin Point, Dessicate or Soft

 

FEATURES
Code 10400.902
Max output power monopolar pure CUT
400 W – 300 Ω
Max output power monopolar cut-coag CUT80%
300 W – 300 Ω
Max output power monopolar cut-coag CUT60%
250 W – 300 Ω
Max output power monopolar cut-coag CUT40%
200 W – 300 Ω
Max output power monopolar cut ENHANCED
250 W – 500 Ω
Max output power monopolar cut-coag BLEND
250 W – 300 Ω
Max output power monopolar coag SPEEDY
120 W – 500 Ω
Max output power monopolar coag DEEP
120 W – 200 Ω
Max output power monopolar coag SPRAY
100 W – 2000 Ω

Max output power monopolar coag SPRAY ARGON
100 W – 2000 Ω
Max output power bipolar CUT
120 W – 50 Ω
Max output power bipolar cut-coag CUT80%
120 W – 50 Ω
Max output power bipolar cut-coag CUT60%
120 W – 50 Ω
Max output power bipolar cut-coag CUT40%
100 W – 50 Ω
Max output power bipolar cut-coag BLEND
120 W – 150 Ω
Max output power bipolar coag COAG
120 W – 50 Ω
Vessel sealing
200 W – 50 Ω

Working frequency Monopolar / Bipolar
425 kHz / 525 kHz
Patient circuit
F
Selectable input voltage
115 – 230 Vac
Mains frequency
50 – 60 Hz
Electrical input power
1000 VA

Size WxHxD
470x150x400 mm
Weight
17,5 Kgs

 

CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self check control
H.F. Leakage currents control
Compensation of mains fluctuation

 

SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Level of protection provided by housing: IP21
Electrical classification: CF
MDR 2017/745/UE Class: II b

 

CONTACT US
Fill out contact form for commercial information about our products.

 

    Are you a healthcare professional?

     

    By selecting "YES", you confirm that you belong to the category above. Otherwise, by choosing "NO" you will be redirected to the contact page of LED SpA.

     

    The information in this section is reserved exclusively for healthcare professionals, as it concerns medical devices whose use or intervention is intended for qualified health care professionals.